How Much Insulation Does Your Attic Need
The right amount of attic insulation depends on your climate and current levels. Use this guide to find your target R-value and calculate how much to add.
Recommended R-Values by Climate Zone
| Climate Zone | If Adding to Existing | If Starting Fresh | Depth (Blown) |
|---|---|---|---|
| Zone 1 (Miami, Hawaii) | R-30 to R-49 | R-30 to R-60 | 10-20" |
| Zone 2 (Houston, Phoenix) | R-38 to R-49 | R-38 to R-60 | 13-20" |
| Zone 3 (Atlanta, Las Vegas) | R-38 to R-49 | R-38 to R-60 | 13-20" |
| Zone 4 (Seattle, DC, St. Louis) | R-38 to R-60 | R-49 to R-60 | 13-20" |
| Zone 5 (Denver, Chicago, Boston) | R-38 to R-60 | R-49 to R-60 | 16-20" |
| Zone 6 (Minneapolis, Buffalo) | R-38 to R-60 | R-49 to R-60 | 16-20" |
| Zone 7 (Duluth, Maine) | R-49 to R-60 | R-49 to R-60 | 16-20+" |
Source: Department of Energy IECC recommendations
How to Measure Your Current Insulation
- 1Access your attic safely using a ladder and flashlight. Step only on joists or a sturdy board.
- 2Locate an area away from the hatch where insulation is undisturbed.
- 3Insert a ruler or tape measure straight down to the attic floor.
- 4Note the depth and insulation type (pink/yellow fiberglass, gray cellulose, etc.).
- 5Measure in at least 3-4 spots—coverage is often uneven.
- 6Check edges near eaves where insulation is often thinner or missing.
R-Value by Insulation Type
| Insulation Type | R-Value per Inch | Depth for R-49 |
|---|---|---|
| Blown Fiberglass | 2.2-2.7 | 18-22 inches |
| Blown Cellulose | 3.2-3.8 | 13-16 inches |
| Fiberglass Batts | 3.0-3.8 | 13-16 inches |
| Mineral Wool Batts | 3.3-4.2 | 12-15 inches |
Calculate How Much to Add
Important Tips
Frequently Asked Questions
How do I measure my current insulation?
Use a ruler to measure from the top of the insulation to the attic floor/ceiling joists. Measure in several spots since coverage may be uneven. For fiberglass batts, measure the full loft, not compressed depth.
What if I have different insulation types layered?
Measure each layer separately and calculate R-value for each. Add them together for total R-value. Old, compressed insulation should be calculated at its actual depth, not original specifications.
Is more insulation always better?
There are diminishing returns. Going from R-11 to R-38 provides huge savings, but R-38 to R-60 provides smaller incremental savings. Cost-effectiveness depends on your climate and energy costs.
Should I remove old insulation before adding more?
Usually no—adding to existing insulation is more cost-effective. Remove old insulation only if it's damaged, moldy, or contaminated with pests. Vermiculite insulation may contain asbestos and needs professional testing.